{"id":26625,"date":"2022-10-18T08:13:43","date_gmt":"2022-10-18T08:13:43","guid":{"rendered":"https:\/\/goldeneagle-worldwide.com\/?post_type=product&#038;p=26625"},"modified":"2023-04-06T08:40:22","modified_gmt":"2023-04-06T08:40:22","slug":"super-golden-sg-24ch24001","status":"publish","type":"product","link":"https:\/\/goldeneagle-worldwide.com\/ar\/product\/super-golden-sg-24ch24001\/","title":{"rendered":"SUPER GOLDEN SG-24CH24001"},"content":{"rendered":"<table>\n<tbody>\n<tr>\n<td colspan=\"3\">SUPER GOLDEN Africa On\/Off R410A split AC<\/td>\n<td>COOLING &amp; HEATING<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Fixed speed (R410A)<\/td>\n<td>SUPER GOLDEN SG-24CH24001<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Rated Power supply<\/td>\n<td>1Ph \/ 220-240V\/50Hz<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Workable Power supply<\/td>\n<td>1Ph \/ 165-260V\/50Hz<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"5\">Cooling<\/td>\n<td>Capacity (btu\/h)<\/td>\n<td>24000<\/td>\n<\/tr>\n<tr>\n<td>Capacity (W)<\/td>\n<td>6950<\/td>\n<\/tr>\n<tr>\n<td>Input (W)<\/td>\n<td>2400<\/td>\n<\/tr>\n<tr>\n<td>Rated current (A)<\/td>\n<td>10.43<\/td>\n<\/tr>\n<tr>\n<td>EER (W\/W)<\/td>\n<td>2.90<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"5\">Heating<\/td>\n<td>Capacity (btu\/h)<\/td>\n<td>24000<\/td>\n<\/tr>\n<tr>\n<td>Capacity (W)<\/td>\n<td>7000<\/td>\n<\/tr>\n<tr>\n<td>Input (W)<\/td>\n<td>2400<\/td>\n<\/tr>\n<tr>\n<td>Rated current (A)<\/td>\n<td>10.43<\/td>\n<\/tr>\n<tr>\n<td>COP (W\/W)<\/td>\n<td>2.92<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Max. input consumption (W)<\/td>\n<td>3200<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Max. current (A)<\/td>\n<td>14.50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"3\">Compressor<\/td>\n<td>Type<\/td>\n<td>Rotary<\/td>\n<\/tr>\n<tr>\n<td>Brand<\/td>\n<td>GMCC<\/td>\n<\/tr>\n<tr>\n<td>Model name<\/td>\n<td>PA240G2CS-7KTM<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"11\">Indoor unit<\/td>\n<td rowspan=\"2\">Indoor Coil<\/td>\n<td>Fin material<\/td>\n<td>Golden&amp; hydrophilic<\/td>\n<\/tr>\n<tr>\n<td>Tube outside dia.and material<\/td>\n<td>\u03a67mm, inner Grooved<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Indoor air flow (Hi\/Mi\/Lo) (M3\/h)<\/td>\n<td>1050\/950\/800<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Rated input Power(cooling\/heating) (W)<\/td>\n<td>80<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Rated current (cooling\/heating) (A)<\/td>\n<td>0.35<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Moisture Removal (KG\/h)<\/td>\n<td>2.6<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Noise level(Hi\/Mi\/Lo) (dB)<\/td>\n<td>49\/47\/45<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Unit dimension (W*H*D)<\/td>\n<td>970X310X230<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Packing (W*H*D)<\/td>\n<td>1035X380X310<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Net weight (KGs)<\/td>\n<td>14.5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Gross weight (KGs)<\/td>\n<td>17<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"8\">Outdoor unit<\/td>\n<td rowspan=\"2\">Outdoor coil<\/td>\n<td>Fin material<\/td>\n<td>Golden&amp; hydrophilic<\/td>\n<\/tr>\n<tr>\n<td>Tube outside dia.and material<\/td>\n<td>\u03a67mm, Inner Grooved<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Noise level (dB)<\/td>\n<td>53<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Unit dimension (W*H*D) (mm)<\/td>\n<td>880X597X330<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Packing (W*H*D) (mm)<\/td>\n<td>945X430X670<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Net weight (KGs)<\/td>\n<td>50<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Gross weight (KGs)<\/td>\n<td>57<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\">Refrigerant type<\/td>\n<td>R410A<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" rowspan=\"4\">Refrigerant pipe<\/td>\n<td>Liquid side (mm)<\/td>\n<td>\u03a66<\/td>\n<\/tr>\n<tr>\n<td>Gas side (mm)<\/td>\n<td>\u03a615.88<\/td>\n<\/tr>\n<tr>\n<td>Max. refrigerant pipe length (m)<\/td>\n<td>15<\/td>\n<\/tr>\n<tr>\n<td>Max. difference in level (m)<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Operation temperature range<\/td>\n<td>-8\u2103-48\u2103<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Ambient temperature range<\/td>\n<td>-8\u2103-53\u2103<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Application area (MM2)<\/td>\n<td>30\uff5e55<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">Sets per 40ft HQ<\/td>\n<td>182<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>SUPER GOLDEN Africa On\/Off R410A split AC COOLING &amp; HEATING Fixed speed (R410A) SUPER GOLDEN SG-24CH24001 Rated Power supply 1Ph \/ 220-240V\/50Hz Workable Power supply 1Ph \/ 165-260V\/50Hz Cooling Capacity (btu\/h) 24000 Capacity (W) 6950 Input (W) 2400 Rated current (A) 10.43 EER (W\/W) 2.90 Heating Capacity (btu\/h) 24000 Capacity (W) 7000 Input (W) 2400 [&hellip;]<\/p>","protected":false},"featured_media":26632,"template":"","meta":[],"product_cat":[228],"product_tag":[374,375,373],"class_list":["post-26625","product","type-product","status-publish","has-post-thumbnail","hentry","product_cat-air-conditioners","product_tag-nitrogen","product_tag-oxytech","product_tag-super-golden"],"_links":{"self":[{"href":"https:\/\/goldeneagle-worldwide.com\/ar\/wp-json\/wp\/v2\/product\/26625","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/goldeneagle-worldwide.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/goldeneagle-worldwide.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":1,"href":"https:\/\/goldeneagle-worldwide.com\/ar\/wp-json\/wp\/v2\/product\/26625\/revisions"}],"predecessor-version":[{"id":26626,"href":"https:\/\/goldeneagle-worldwide.com\/ar\/wp-json\/wp\/v2\/product\/26625\/revisions\/26626"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/goldeneagle-worldwide.com\/ar\/wp-json\/wp\/v2\/media\/26632"}],"wp:attachment":[{"href":"https:\/\/goldeneagle-worldwide.com\/ar\/wp-json\/wp\/v2\/media?parent=26625"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/goldeneagle-worldwide.com\/ar\/wp-json\/wp\/v2\/product_cat?post=26625"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/goldeneagle-worldwide.com\/ar\/wp-json\/wp\/v2\/product_tag?post=26625"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}